Cleanroom hoods
Cleanroom hood with integrated mask, non-sterile
Schematic illustration, not a product photo. Series photos will follow with sample approval.
In preparationThis article belongs to the new ProSafe cleanroom line and is not yet available. All technical figures are target specifications for series production, not product commitments. Test reports, conformity documents and sterilisation validations will be supplied with the release of the series.
Article code: P019
Version
We deliver this article after the release of the series. With your enquiry we register you for pre-series samples, test reports and the delivery date; we reply within 24 hours.
Separate flat-top hood with built-in tie mask and two pairs of ties.
Description
Hood and mask in one piece shorten gowning and avoid gaps between hood and mask edge.
The hood covers head, hair, neck and shoulders. Hair and scalp are among the strongest particle sources on a person, which is why the hood is mandatory in aseptic areas. Separate hoods are worn under the coverall's mandarin collar; the shoulder yoke prevents an open gap at the neck.
Shape and elastic determine how well mask and goggles seat. A straight forehead edge with flat side panels lets the goggles seal, and the elastic in the chin area keeps the hood closed without pressing on the forehead. Hoods with an integrated mask combine both parts.
The integrated mask is tied with two pairs of ties; hood shape and shoulder yoke match the hood without mask, with pattern and dimensions approved separately on the sample.
Features
- Flat-top hood with straight forehead edge
- Integrated tie mask with bendable nose strip
- Elastic in the chin area, long shoulder yoke
- Aseptically folded
Typical applications
- Aseptic areas with a separate mandarin-collar coverall
- Combination with a frock in ante-rooms and laboratories
- Operations that change hood and coverall separately
- Areas with goggles where the forehead should stay flat
What to consider when choosing
- With or without mask: The mask hood saves a step; the separate mask allows a change without the hood.
- Delivery condition: Sterile, individually packed for GMP A/B; non-sterile, 20 per bag for controlled areas.
- Fit: The shoulder yoke must fit under the coverall collar; combinations within the line are matched.
Technical details
| Article code | P019 |
|---|---|
| Delivery condition | non-sterile |
| Material | Hood: PP/PE laminate, 60 g/m². Mask: spunbond polyester outer, meltblown filter layer, PP/PE nonwoven inner, polyester ties |
| Dimensions | Pattern dimensions are set with the approved reference sample |
| Sizes | One size |
| Pack size | 20 pieces per double bag; 7 outer bags per carton = 140 pieces; carton 28 × 43 × 31 cm |
| Target environment | ISO Class 4 and 5 cleanrooms and controlled areas; GMP use subject to the operator's own assessment |
| Supply | on request after release of the series, quote with price and pack size |
Target specification (design targets)
Target values for series production. They describe what we design material, construction and testing for and are not a commitment for the delivered article. Lot test reports will be supplied with the series.
| Basis weight | 60 g/m², tolerance ±2 g/m² |
|---|---|
| Hydrostatic head | minimum 100 mm H₂O |
| Particle shedding (Helmke drum) | Category I to IEST-RP-CC003 |
| Surface resistivity | typically 10⁷ to 10¹⁰ Ω |
| Chemical permeation (ASTM F739) | Carmustine 30 min, thiotepa 60 min; cisplatin, cyclophosphamide, doxorubicin, etoposide, fluorouracil, methotrexate, paclitaxel over 480 min (ASTM F739, design target) |
| Mask: filtration | PFE 94 % (0.1 µm), BFE 97 %, differential pressure 6.8 mm H₂O/cm² (design targets) |
| Shelf life | 5 years from manufacture |
| Storage | Dry and cool below 40 °C, away from direct sunlight |
Standards framework
Standards and regulations the series is to be tested and marked against. Conformity will be demonstrated with the release of the series.
- PPE Regulation (EU) 2016/425, Category III (planned)
- EN ISO 13982-1 (Type 5) / EN 13034 (Type 6) or PB [6]
- EN 14325 (material tests)
- IEST-RP-CC003 (particle shedding, Helmke drum)
Notes on use
Hoods are single-use products. Put on the hood first, then close the mandarin-collar coverall over it so the shoulder yoke is covered. With an integrated mask, shape the nose strip and tie the ties behind the head.
Frequently asked questions
Does the hood fit every coverall?
The hoods of this line are matched to the line's mandarin-collar coveralls. With other makes, check the collar height on a sample.
Why a straight forehead edge?
It keeps the forehead free of folds so that goggles seal and no hair escapes.
When will this article be available?
The article is in preparation. With your enquiry we register you for pre-series samples and the delivery date; test reports and conformity documents follow with the release of the series.
Related: Cleanroom hoods · All articles · Garment system